Overview:Nominal deviation is also an important parameter of photovoltaic modules, which is generally acceptable within (+3%). This shows that although the nominal parameters of the components are the same, the output characteristic curves are different in practice, which results in the reduction of the efficiency caused by the inconsistent current when multiple components are connected in series. At present, component manufacturers such as Tianhe and Yingli usually use positive deviation to reduce the loss caused by power mismatch.

The Effect of Equipment on System Efficiency


I think the equipment factor is the most important factor affecting the efficiency of photovoltaic system.


1. Matching Degree of Photovoltaic Modules


Nominal deviation is also an important parameter of photovoltaic modules, which is generally acceptable within (+3%). This shows that although the nominal parameters of the components are the same, the output characteristic curves are different in practice, which results in the reduction of the efficiency caused by the inconsistent current when multiple components are connected in series. At present, component manufacturers such as Tianhe and Yingli usually use positive deviation to reduce the loss caused by power mismatch.


2. Efficiency of Inverter and Box Converter


Although the European efficiency in the technical specifications of inverters takes into account the weighted conversion efficiency of different load rates, few inverters can achieve 98.5% of the current common use in practice. In the process of converting DC to AC, the weighted efficiency of 97.5% should be good.


The MPPT tracking effect of different inverters is also different. When the maximum power point voltage varies with the irradiance, the inverters need to constantly change the voltage value to find the maximum power point voltage, which will also cause energy loss due to the lag of tracking. At present, some inverters manufacturers adopt multi-channel MPPT to reduce this loss.


Within the maximum DC input voltage range, increasing the voltage and reducing the current of the multi-series components as far as possible can improve the conversion efficiency of the inverter and reduce the line loss.


The box transformer will inevitably lose energy in the process of boosting, which is determined by the parameters of the box transformer, generally about 1.5%.

Aluminum Ground Pv Mounting System Made In China

3. DC Line Loss and AC Line Loss


The area of a 1MW unit is about 3.5-4 hectares. It takes a long DC line to send electricity from such a large area of photovoltaic modules to a place. There are two ways to reduce line loss: choose good cable and increase voltage. In general, the DC line loss can be estimated by 2-3%.


The AC line is short and the line loss is relatively small. Generally, it can be estimated by 1%.


4. Fault Of Equipment


An important reason for the low efficiency of the system caused by equipment failure and overhaul. The following figure shows the causes of photovoltaic power plant failures, half of which are from equipment.


About Serve Energy

Serve (Xiamen) New Energy Co., Ltd. is a Chinese manufacturer of low ballasted aluminum PV mounting system with independent intellectual property rights. Serve Energy specializes in the research and development, production, sales and services of solar products, such as aluminum ground PV mounting system made in China, wholesale triangle aluminum PV mounting system from China, good quality BIPV carport system from China, steel & aluminum combined ground PV mounting system.


Message BoardPlease write down your question and we will respond to you within 24 hours.